check_refrigerant_switzerland
shallowcom.thenewengineer/hvac · Verify this server
DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the regulation's annexes and thresholds, never from a language model's estimate. Every step is auditable. Swiss refrigerant regulation check (ORRChim / ChemRRV annex 2.10, OFEV synthesis of May 2026, rules adopted 29.10.2025) plus refrigerant data from EN 378-1 Annex E: GWP (AR4, the ORRChim basis), ODP, LFL, safety class, practical limit. Returns, for a given refrigerant and installation: the date from which machines using it can no longer be placed on the Swiss market (import from 01.01.2027, sale to third parties from 01.07.2027), the date from which filling with virgin refrigerant is banned, the period when only reclaimed refrigerant may be used, and the date from which all filling is banned. SCOPE: heating, air conditioning, building cooling and process cooling, data centres included. NOT food refrigeration, cold rooms or deep freezing: those are a different trade, and the tool declines them instead of answering. Use it whenever the user asks about a refrigerant in Switzerland — its GWP / PRG, flammability, whether a chiller, heat pump, split, VRF or cold room using it may still be sold or refilled — in any language: fluide frigorigène, Kältemittel, refrigerante, refrigerant, R-32, R-410A, R-290, CO2, NH3... The answer depends on the installation. The regulation distinguishes: use (building cooling, food refrigeration medium / low temperature / combined / deep freezing, process cooling, heat pump mainly for heating, ice rink), cooling capacity Q0K or heating capacity Q0H, self-contained (factory-built packaged unit) or not, split, direct expansion (incl. VRF), secondary coolant loop (chilled water / brine), air-cooled condenser and refrigerant charge. THIS TOOL ANSWERS ONE QUESTION ONLY: may the refrigerant still be sold and refilled in Switzerland, and until when. It says NOTHING about safety in the room - charge limits, machine room, detection, ventilation, ATEX. That is `check_en378_zones`. A question that mixes both - « may I use R-32 for 3 kg in a server room, and until when can I refill it » - needs BOTH tools: call this one for the dates, and check_en378_zones for the room. Do not answer half the question. NEVER guess these. Call the tool with what the user gave: it returns `provisional: true`, the possible `scenarios`, and `questions_to_ask` in the order that matters most. Ask them (one or two at a time), then call again. Natural refrigerants need no questions. Build your answer on `answer_outline`; quote exceptions as possible, never as granted.
1 trials · measured 1 day ago
check_refrigerant_switzerland scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.thenewengineer/hvac, measured 6 Oct 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- self-provisionable
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-10-06 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/f0edb77a-c1bf-4b84-adab-a18b03178c07)