get_product_recalls
shallowcom.keyvex/keyvex · Verify this server
Returns safety recalls from federal agencies — drug recalls (FDA), medical device recalls (FDA), food/dietary supplement recalls (FDA), and (coming in v1A.1) vehicle recalls (NHTSA) and consumer-product recalls (CPSC). Use this when the user asks about: recent recalls for a specific company or product, FDA Class I (most severe) recalls, active vehicle recalls by make/model, food contamination recalls, drug shortages and recalls, or to add a 'product-safety event' flag to insider activity / 8-K filings / enforcement actions. Sources (filter via the `source` enum): fda_drug — openFDA /drug/enforcement.json. Drug recalls including prescription, OTC, biologics. Class I/II/III severity. fda_device — openFDA /device/enforcement.json. Medical device recalls (implants, diagnostics, equipment, software). Same classification scheme. fda_food — openFDA /food/enforcement.json. Food + dietary supplements. Pathogen contamination, allergen mislabeling, etc. cpsc — saferproducts.gov RestWebServices/Recall. Consumer-product recalls (clothing, electronics, toys, batteries, etc.). No severity classification; classification field is null. nhtsa — Vehicle, tire, equipment, child-seat recalls. Deferred to v1A.1 (api.nhtsa.gov bulk endpoint pending investigation). Cross-source pairing pattern: Recall → 8-K Item 7.01/8.01: pair with get_material_events Recall → insider sells: pair with get_insider_transactions Recall → SEC/DOJ follow-on: pair with get_enforcement_actions Recall → company filings: pair with get_proxy_filings (DEF 14A risk factors) Each record is one recall. Identifier format: `{source}-{recall_number}` (e.g., 'fda_drug-D-1234-2026'). FDA classifications: Class I — serious adverse health consequence or death Class II — temporary or reversible health consequence Class III — unlikely to cause adverse health consequence Source freshness (per-source publication cadence, not KeyVex bug): CPSC publishes within ~1-2 days; recent data flows hourly-fresh. openFDA's snapshot updates every ~10-14 days, and each snapshot carries recall_initiation_date values that LAG the snapshot date by another 30-45 days (the time between FDA classifying a recall and openFDA exposing it). Net: FDA records in this collection typically run ~4-6 weeks behind real-world recall dates, while CPSC is current. A default desc-by-date sort therefore looks CPSC-heavy at the top even when FDA matters more for the query. Filter by source='fda_*' to see FDA-only and avoid the skew. classification filter scope: 'classification' is an FDA-only field. CPSC records always have classification=null (CPSC doesn't use the FDA severity scheme). Filtering by classification excludes ALL CPSC rows by definition. The query response surfaces this with a notice in coverage_warning when the filter is set.
1 trials · measured 1 day ago
get_product_recalls scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.keyvex/keyvex, measured 6 Oct 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- self-provisionable
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-10-06 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/c4a2b6ee-9ea1-4cdb-b98c-e13fcc432fc6)