apply_ifc_rules
shallowcom.thenewengineer/hvac · Verify this server
Turn what you read in the overview into rules the tool replays on EVERY piece of the model, including the ones you were never shown. THIS IS HOW THE TOOL LEARNS A MODEL. read_ifc_overview gives you some fifty groups — one per object type, not one per piece. You answer with RULES on those groups, and this tool applies them to the three thousand pieces. You never give a verdict piece by piece: the result stays deterministic because a program, not you, does the matching. THEN READ THE ANSWER BACK, AND EXPECT TO POST AGAIN. The answer gives every group with the role your rules gave it and how many pieces that is. A rule that is too wide shows up on one line — « Gaine rectangulaire cadree, 471 pieces, centrale_de_traitement_d_air » is a rule that turned every duct into an air handling unit. Narrow it and post again. Calling this tool costs nothing and may be repeated as often as you need. WHAT NEEDS A ROLE, AND WHAT DOES NOT. Plain ducts and fittings need none: they are network by nature, and the answer marks them segment_ou_raccord so you can see at a glance whether a rule caught them by mistake. What needs a role is everything else — air handling units, fans, fire dampers, balancing dampers, silencers, louvres, diffusers — plus whatever must be kept OUT of the network, such as access zones, equipment plinths or damper motors. TWO ROLE NAMES ARE FIXED, because circuits start from them: give air handling units, monoblocs and ventilation casings the role centrale_de_traitement_d_air, and fans the role ventilateur - exactly these words. ONLY EQUIPMENT THAT MOVES THE AIR gets one of them: a unit is a box with a fan in it. Heating and cooling coils, heat exchangers, filters, silencers, dampers, fire dampers, VAV boxes, humidifiers are NOT units: the air runs through them, they are pieces of the network. Give them another role (coil, silencer, damper...) or none - never one of the two unit roles. A coil in 'equipements' is a rule that is too wide. The answer lists, under 'equipements', the GUIDs of every piece of the model that got one of the two roles: that list is what trace_duct_circuits starts from, and what the pages show as units. Every other role name is yours to choose. ORDER THE LIST YOURSELF, most specific first, down to the most general. The fire damper rule must come before the balancing damper rule, or « damper » takes everything. Equipment must come before terminals: « VEN_MSF_MONOBLOC_SIMPLE_FLUX_REPRISE » contains « reprise », and a return-diffuser rule placed first would claim the air handling unit. Pieces no rule catches are simply listed, with no warning and no failure: the engineer judges on the 3D view, not on a coverage report. NEXT: once 'equipements' lists the air handling units and fans you expect, call trace_duct_circuits with only the token. It computes nothing yet: it checks that the units are connected to the networks and returns the complete list of units and fans, to choose from - see trace_duct_circuits. 'equipements' counts every piece ('pieces') but lists at most thirty names: the count, not the list, is the model.
1 trials · measured 35 days ago
apply_ifc_rules scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.thenewengineer/hvac, measured 20 Oct 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- self-provisionable
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-10-20 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/ab60ff1e-37f6-4c10-9896-840027767a9f)