compute_bored_pile_wall
shallowcom.civilquants/civilquants · Verify this server
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Cast-in-place bored concrete pile retaining wall, the SEVENTH member of the wall family and the FIFTH of the retaining_walls L1 leaf. The SIXTH structural system in the retaining / earth-structures domain (after mass concrete / RC / steel / mesh-and-stone / reinforced-soil-with-facing). Four structural forms via the bored_pile_form discriminator: CONTIGUOUS (clear-spaced piles, shotcrete face), SECANT_HARD_SOFT (alternating soft/hard overlapping piles, intermediate watertightness), SECANT_HARD_HARD (overlapping RC piles, maximum watertightness; deep basements), and KING_POST_AND_LAGGING_RC (widely-spaced RC king posts with lagging panels). 18th use of the classed-then-legacy attribute discrimination pattern, applied via the CONCRETE_REINFORCED handler's new wall_type='bored_pile' branch for the capping beam (when included). Routes via five new WorkCategory entries (BORED_PILE_CONCRETE, BORED_PILE_BORE, BORED_PILE_NR, BORED_PILE_HEAD_PREP, BORED_PILE_INTERLOCK) covering the CESMM4 Class P §P.8 three-line cast-in-place pile measurement convention plus the Class Q ancillaries head-prep line and the secant-specific interlock line. Codes: CESMM4 P.8.1-4 + Q.1.1, NRM2 7.6.1-4 + 7.5.1, MMHW 1600.5-6 (SHW Cl. 1602/1603), and SMM7 D30.1-5 — D30 (Cast in place piling) is OPENED at this session as the conventional UK QS named home. Capping beam routes via CONCRETE_REINFORCED with wall_type='bored_pile' to F.6.5 / 11.3.5 / 1700.4.4 / E10.3.4. Reinforcement billed itemised (separate audit line per BS 8666:2020 cage) on top of the pile rate by S31 decision. Eight variant presets exercise all four BoredPileForm values (2/2/2/2 split). Example params: wall_length_m=20 m (5–200), retained_height_m=6 m (2–20), embedment_below_formation_m=4 m (1–15). Example call: {"params": {"wall_length_m": 20, "retained_height_m": 6, "embedment_below_formation_m": 4}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
1 trials · measured 2 days ago
compute_bored_pile_wall scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.civilquants/civilquants, measured 31 Aug 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- open
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-08-31 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/726a21cf-4d32-4ea7-aa79-9856e8731d99)