water_content_from_vessel
shallowcom.thenewengineer/hvac · Verify this server
DETERMINISTIC: the same inputs always give the same result — from any AI, on any day. Figures come from the standard's tables and formulas, never from a language model's estimate. Every step is auditable. Deduce the water content of an installation from the expansion vessel already fitted. WHAT THIS IS FOR. Refurbishment, and site visits with no drawings. Sizing a new vessel, a new pump or a new generator needs the water content, and on an existing installation nobody has it: the drawings are lost, or never matched what was built. The vessel on the wall is the one piece of evidence still standing, and it was chosen from that very figure. ASK THE OPERATOR FIRST. Whoever filled or refilled the system knows the real figure — from the meter, the filling station, or the maintenance log — and that figure beats any deduction. This tool is what you use when nobody knows, or to check a number that looks wrong. It gets the conversation moving; it does not close it. HOW. The sizing calculation is run backwards: a trial water content is fed to the EN 12828 sizing, the resulting vessel is compared with the one on site, and the trial is adjusted until they match. The formulas are never rewritten in reverse — the answer cannot contradict the direct calculation, because it is the same code. WHAT THE ANSWER IS WORTH. A vessel is picked from a catalogue range: a 200 L unit covers everything needing between 141 and 200 L. The result is therefore A RANGE, never a single figure. And an oversized vessel — common — will overstate the content. Compare the range with what you see on site; it does not replace looking. It also assumes the vessel was sized correctly in the first place. If it was not, the deduction inherits the mistake — which is itself worth knowing: a range far from what the installation plainly holds means the vessel is wrong, and that is a finding in its own right.
1 trials · measured 2 days ago
water_content_from_vessel scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.thenewengineer/hvac, measured 6 Oct 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- self-provisionable
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-10-06 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/3c039ec6-d073-4932-b2c3-1440b59a4164)