trace_duct_circuits
shallowcom.thenewengineer/hvac · Verify this server
THE CIRCUITS THE FANS OF A MODEL ARE SIZED ON, found without anyone clicking and computed on the pressure-drop page, where the user confirms types and flows and reads the pressure drops. ONLY UNITS AND FANS ARE EXCHANGED. The tool never sends you system names: it sends the air handling units and fans your rules found, each with what the network walk finds connected to it - geometry, not names. A unit is equipment with a FAN - air handling unit, monobloc, ventilation casing, fan. Coils, heat exchangers, filters, silencers, dampers are network pieces: if one shows up in the list (often as 'dans_le_reseau_de' another unit), your rules are too wide - fix them with apply_ifc_rules before choosing. FIRST THE CHECK AND THE LIST, THEN THE CALCULATION. Called with only the token, once your rules are posted with apply_ifc_rules, it computes NOTHING and bills nothing. It walks the networks from every unit and fan and measures the share of the model's air pieces they reach ('raccordement'). Two answers: - CONNECTED (half of the air pieces or more): the COMPLETE list of units and fans ('centrales_et_ventilateurs', each with its number of connected networks) and 'lien_centrales', a VIEW-ONLY page - every unit in a light colour with its name floating above it, each of its networks in the same colour. Give the user that link and say nothing is computed yet. Then: * the user named units, even loosely: map their words onto the EXACT names of the list, say which you picked, and call again with units; * the user asked for the whole model and the list says 'tous_possible' (50 air networks or fewer): call again with all_networks=true; * otherwise show the user the WHOLE list to tick - every unit and fan, however long; never only the main ones. 'Tous' first when it is offered, then one numbered line per unit with its number of connected networks; mark the units connected to nothing. Filter only on what the user said, and then say which filter and how many lines it left out. Call with what they tick. - NOT CONNECTED ('non_raccorde': less than half, or no unit at all): tell the user the sentence of 'A_DIRE_A_L_UTILISATEUR' - « Nous n'avons pas pu connecter les centrales de traitement d'air aux réseaux de votre modèle », in their language - and suggest the pressure-drop page ('lien_pdc'), where they define each network themselves by a start and an end. Nothing is computed. If your rules missed units, fix them and call again. WHAT IS COMPUTED: for each network connected to a chosen unit or fan, the LONGEST path. Networks connected to no unit are not computed here. BEYOND 50 AIR NETWORKS, THE MODEL IS COMPUTED ONE UNIT AT A TIME. Each call computes ONE unit - unit_name, or units with a single name - or the network of ONE piece - network_guid. The whole model, start_role and several units are refused: nothing is computed, and the answer says why. Ask the user which unit, or which piece: on the view-only page, hovering a piece shows its GUID. Call again for the next one; what is computed stays, and is not billed again. YOU SEE A SAMPLE IN THE OVERVIEW, THE WHOLE MODEL HERE. Never choose the units from what read_ifc_overview showed you - one example per type: choose from the list this tool returns. A REQUEST THE TOOL CANNOT MATCH. Names that match nothing come back under 'non_reconnus', each with the closest names; the names that did match are computed. If NOTHING matched - or the GUID or unit_name is unknown - nothing is computed, whatever the size of the model: the list comes back, with the closest names under 'non_reconnus' and what went wrong under 'demande_non_satisfaite'. Correct the names from the list, or ask the user which one they meant, and call again. A PIECE INSTEAD OF A UNIT. When the model has no unit, when the unit the user means was not recognised, or when they simply show a piece: network_guid computes the network of any piece - the tool finds where its air starts; end_guid computes one circuit to that end - from start_guid if given, else from the start the tool finds. A start found by the tool comes back under 'depart_trouve' with what made it chosen: say so, and ask the user to check it on the 3D link. The user gets a GUID by hovering a piece on the view-only page. These work on complex models too: they designate one network. ONE UNIT BY ITS NAME. unit_name computes the unit or fan of that name, found among all the pieces - units does the same for several. start_guid starts from one part - an air handling unit, a fan, a duct - and computes the network it belongs to, nothing else. The answer says so under 'portee' and lists the model's other units and fans under 'autres_departs': tell the user the result is partial. From each starting part it keeps ONE CIRCUIT PER BRANCH: the longest path in metres of each branch. From an air handling unit, that is one circuit per network connected to it - supply, return, intake, exhaust. EACH OF THESE CIRCUITS IS COMPUTED, and becomes a circuit of the model: it has a name, a COLOUR, and a tab on the website. All the circuits of one unit or fan share THAT UNIT'S colour; on the page, its networks show in a light version of it, and networks connected to no unit in grey. WHAT YOU GET portee what the call covers: the whole model, one role, or one part's network only. circuits one per branch: name, colour, length, its unit, its current type, the flow used at the start and where it came from. NO PRESSURE DROP: see below. autres_arrivees shorter paths, found but NOT computed. lien_3d the calculation page: every unit's networks in its colour, its circuits in a deeper shade. lien_centrales the view-only page of the units and their networks. lien_classeur the Excel workbook of the computed circuits: the supply / return box and the flows are corrected there and everything recalculates. Give it too (a free account is needed to download it). metre the take-off of the whole network. IF A CIRCUIT IS STILL 'calcul', call again with THE SAME ARGUMENTS a moment later. Nothing is recomputed and nothing is billed again: an identical call only reads. A different velocity or flow is applied to the circuits already there, without a new analysis. HOW TO USE IT WELL. Ask the user for the design velocity before calling, or say which one you used. THIS TOOL DOES NOT READ THE FLOW FROM THE MODEL: look for it in the air handling unit's properties with read_ifc_overview and pass it as flow_m3h, one unit at a time - see that argument. Failing that, the flow comes from the design velocity: between two branches, the length-weighted average velocity of the straight ducts equals it, and no duct runs more than 20 % above it. Say which of the two it was. YOU ARE NOT GIVEN THE PRESSURE DROPS, ON PURPOSE. Until the user has confirmed on the page each circuit's type (supply, return, outdoor air, exhaust) and its flows, the pressure drop is wrong - the tool cannot know either. Never estimate, quote or compute one yourself, not even roughly: say the pressure drops are on the page, once the type and the flows are confirmed. Every circuit is computed as a SUPPLY circuit until someone says otherwise: the tool cannot tell supply from return. The flow rates do not depend on it - a duct carries what its section allows either way - but the tee coefficients and the design velocity do. If a branch is a return, an intake or an exhaust, SAY SO and tell the user how to set it in the 3D view: hovering the arrow of a circuit shows its type, and each click on that label moves to the next one - supply, return, outdoor air, exhaust. A click on the arrow itself reverses the air direction, which is how the user says at which end the terminal or the louvre sits when the duct has a constant section. Say that each circuit was chosen BY LENGTH. A shorter path loaded with dampers, bends or silencers can lose more pressure. BEFORE THE LINK, SAY WHAT THE USER MUST CONFIRM ON THE PAGE - see 'A_CONFIRMER_PAR_L_UTILISATEUR', circuit by circuit: whether each network is supply, return, outdoor air or exhaust (all are computed as supply until the user says otherwise), and the flows (which are estimates from the velocity, which were given). Never leave it out: the figures mean nothing until both are confirmed. END YOUR ANSWER WITH THE 3D LINK, on its own line, and urge the user to open it - see 'A_DONNER_A_L_UTILISATEUR'. Name each circuit by its unit, its colour and its type - several circuits share a colour. The page is where the calculation is finished: the user sets the flows (a click on the unit, or typed in the table), the velocity, the air direction and the circuit type, deletes a circuit from its tab - its colour goes with it -, adds one by clicking a start and an end part, and downloads the workbook, one editable sheet per circuit. A FLOW THAT LOOKS WRONG IS AN ESTIMATE, NOT A DEFECT. When none was given, flows come from the design velocity. If you point one out, say in the same breath that the user sets it on the page or in the workbook - see 'debits_et_reglages'. THE USER'S CHOICES STAND. A circuit they deleted is not computed again: it comes back under 'retires_par_l_utilisateur', and only they can restore it, by tracing it on the page. A circuit they traced by hand is never replaced. So after they have been on the page, call this again before stating any figure - never answer from memory.
1 trials · measured 36 days ago
trace_duct_circuits scores 100.0/100 on Vouch's measured behaviour index, from 1 real invocation trials against com.thenewengineer/hvac, measured 20 Oct 2026 under methodology v0.2.0. Every measured component scored 100.
Component breakdown
| Component | Weight | Value |
|---|---|---|
| Reliability | 35% | not applicable |
| Schema integrity | 25% | 100.0 |
| Failure behaviour | 15% | not applicable |
| Latency | 15% | not applicable |
| Concurrency | 10% | not applicable |
Tool details
- Transport
- remote
- Credential class
- self-provisionable
- Input schema
- not declared
- Output schema
- not declared
- Side-effect classification
- unclassified
Score history
| Day | Score | Tier | Methodology |
|---|---|---|---|
| 2026-10-20 | 100.0 | shallow | v0.2.0 |
Probe evidence
| Probe | Outcomes |
|---|---|
| schema_integrity | pass: 1 |
Raw request/response logs are not archived yet — the outcome counts above are drawn directly from every recorded trial.
Embed this score
Available for every tool, scored or not — not a verification perk. Always links back to this page.
[](https://vouch.tools/tools/18b68da7-f329-41d5-9828-b3665f688f4c)